ENERGY STORAGE/CONVERSION

BATTERY DEVELOPMENT

Herstellung von Hochenergiekathoden für Lithium-Ionen-Batterien mit neuartigem Elektrodenaufbau
 

Anisotropy – Thermal Conductivity Tests of Batteries
 

C3 Portfolio zum Applikationsbereich Batterie
 

EIS in Wetting of Lithium-ion Battery Materials
 

Vergleichsstudien an elektrokatalytischen und photokatalytischen Wasserstofferzeugungskatalysatoren
 

Getting Started With Your First Experiment: EIS300 Electrochemical Impedance Techniques- Potentiostatic Electrochemical Impedance Spectroscopy
 

Cable-capacitance Correction
 

Leitfaden – Anschluss und Parameter für elektrochemische Messungen an Batterien
 

Gleichzeitige Messung beider Halbzellen einer Batterie mit dem Interface 5000
 

Introduction to Non-standard Charge-discharger Cycle Tests: Custom Current Profiles
 

Batterieentwicklung / Batterieforschung: Elektrochemische Charakterisierung von Graphitelektroden in Lithium-Ionen Batterien
 

Application Note Low-Impedance-EIS at its Limits with Ref30K-Booster
FUEL CELL RESEARCH

C3 Portfolio zum Applikationsbereich Brennstoffzelle
 

Total Harmonic Distortion (THD)
 

Electrochemical characterization of a CFY-stack with planar electrolyte-supported solid oxide cells in rSOC operation
 

Vergleichsstudien an elektrokatalytischen und photokatalytischen Wasserstofferzeugungskatalysatoren
 

Katalysatorentwicklung für Brennstoffzellen
CO2 APPLICATIONS

CO2-Abtrennung aus Gasgemischen in Labor-Rührautoklaven
 

Der Einsatz von CO₂ in Druckreaktoren am Beispiel einer gezielten Schaumgebung und Partikelgestaltung
ELECTROCHEMICAL ENERGY

In-situ SANS Messung an elektrischen Doppelschichtkondensatoren
 

Testing Super-Capacitors
 

Testing Electrochemical Capacitors Part 2: Cyclic Charge Discharge and Stacks
 

Testing Electrochemical Capacitors Part 1: CV, EIS, and Leakage Current
 

Testing Lithium Ion Batteries
 

Testing Electrochemical Capacitors: Part 3 – Electrochemical Impedance Spectroscopy
 

EIS Measurement of a Very Low Impedance Lithium Ion Battery
 

Measuring Batteries Using the Right Setup (Dual-cell CR2032 and 18650 Battery holder)
HYDROTHERMAL CARBONIZATION

Zum Einsatz des Büchi Druckreaktors “kiloclave” bei Untersuchungen zur Hydrothermalen Carbonisierung (HTC) von Eichhornia crassipes (Wasserhyazinthe
SPECTROELECTROCHEMISTRY

Spektroskopische Charakterisierung von Radikalionen organischer Substanzen
 

Measuring the Optical Power of your LED
 

Dye Solar Cells – Part 3: IMPS and IMVS Measurements
 

Dye Solar Cells – Part 2: Impedance Measurements
 

DSSC: Dye Sensitized Solar Cells
 

Spectroelectrochemistry – Part 2: Experiments and Data evaluation
 

Spectroelectrochemistry – Part 1: Getting started
 

Raman Spectroelectrochemistry
HYDROGEN STORAGE

Vergleichsstudien an elektrokatalytischen und photokatalytischen Wasserstofferzeugungskatalysatoren
 

In-situ Messung von Hydrierkinetiken an flüssigen Wasserstoffträgern
PRODUCTS FOR THIS APPLICATIONS:





GAMRY INTERFACE 1010 POTENTIOSTAT/ GALVANOSTAT / ZRA
The Interface 1010 is a value oriented, general purpose potentiostat for almost all applications except for high current electrochemistry.

 

GAMRY INTERFACE 5000 POTENTIOSTAT / GALVANOSTAT / ZRA
The Interface 5000 Potentiostat / Galvanostat / ZRA is a compact, inexpensive system for material development and condition testing of batteries, super capacitors and fuel cells

 

GAMRY REFERENCE 620 POTENTIOSTAT / GALVANOSTAT / ZRA
The latest development in the Reference 600 series - the Reference 620 - features 20-bit analog/digital conversion, gaining about a decade of additional sensitivity. This makes the system the first choice for demanding applications, e.g. in basic research.

 

GAMRY REFERENCE 3000 POTENTIOSTAT / GALVANOSTAT / ZRA
The high-end potentiostat for all demanding applications in electrochemistry from very low to high currents.

 

GAMRY REFERENCE 3000 POTENTIOSTAT / GALVANOSTAT / ZRA - AUXILIARY ELECTROMETER (AE)
The well-known high-end Reference 3000AE Potentiostat/Galvanostat/ZRA with eight additional auxiliary electrometers (AE).

 

GAMRY REFERENCE 3000 (AE) AND REFERENCE 30K BOOSTER
The Reference 3000 (AE) Potentiostat/Galvanostat/ZRA high performance and multi-purpose basic unit can be combined with the Reference 30k Booster and is ideal for evaluating new highest-level technologies for batteries, fuel cells, supercapacitors and high turnover electrochemical synthesis.

 

GAMRY INTERFACE 1010 BIPOTENTIOSTAT
The Interface 1010 Bipotentiostat System from Gamry is compact, flexible, and inexpensive for all kinds of electrochemical measurements using two channels.

 

GAMRY MULTI-CHANNEL POTENTIOSTAT WITH INTERFACE POWER HUB (IPH)
Multi-channel systems are ideal for any application where significance can be increased by higher experimental throughput.

 

BUCHI POLYCLAVE
Safety and flexibility for a wide range of pressure applications in steel and glass vessels

 

BUCHI VERSOCLAVE
Flexible and robust- even under high pressure

 

BUCHI UNICLAVE
Compact, modular, excellent price/performance ratio, ss/metal pressure reactor system with 0.5 / 1 liter volumina

 

BUCHI MINICLAVE DRIVE
small volumina – strong magnetic drive

 

BUCHI PICOCLAVE
Safety and flexibility with small scale glass and steel reactors

 

BUCHI KILOCLAVE
Safe pressure reactions up to 20 litres in laboratory/kilo lab or in small scale production

 

BUCHI PILOTCLAVE
Safe pressure application on a pilot scale up to 500 litres

 

BÜCHI MIDICLAVE
Safe and comfortable working under high pressure

 

BUCHI NOVOCLAVE
Reach new dimensions in terms of pressure and temperature

 

BUCHI BPC 2
BPC 2 - gas dosing unit for reliable and reproducible hydrogenation

 

IMX8 (ELECTROCHEMICAL MULTIPLEXER)
The IMX8 (Electrochemical Multiplexer) offers higher experimental throughput by performing automatic sequential measurements. With some limitations compared to multi-channel systems is a cost effective alternative for many applications.

 

GAMRY EIS BOX 1010
The Gamry EIS Box 1010 consists of an Interface 1010 base unit and an electrochemical multiplexer optimized for impedance spectroscopy (EIS) on batteries, fuel cells and super capacitors up to ±12 V.

 

GAMRY EIS BOX 5000
The Gamry EIS Box 5000 consists of an Interface 5000 base unit and an electrochemical multiplexer optimized for impedance spectroscopy (EIS) on batteries, fuel cells and super capacitors up to ±6 V.

 

GAMRY SOFTWARE
Gamry has developed its own software for each important application in electrochemistry and offers a very simple and intuitive handling through open source scripting, flexible and uncomplicated, even the customized experiment as well as with other programming languages such as LabView, C++, etc.

 

GAMRY UV VIS NIR SPECTROELECTROCHEMISTRY
For synchronization of spectroscopic information with the electrochemical change of a redox pair Gamry offers the right system from UV to NIR

 

GAMRY RAMAN SPECTROELECTROCHEMISTRY
Synchronization of electrochemical changes of a redox reaction with complex scattered light spectroelectrochemistry or Raman spectroelectrochemistry

 

GAMRY CONDUCTIVITY MEASURING CELL FUMATECH MK 3
The MK 3 simulates with high accuracy typical fuel cell conditions for conductivity measurements via electrochemical impedance spectroscopy in combination with the Gamry System Reference 600+ or Interface 1010E.

 

GAMRY LITHIUM BATTERY MATERIALS CELL KIT
The design of the Lithium Battery Materials Cell Kit allows very flexible investigation of electrode materials of a lithium-based galvanic cell.

 

GAMRY UNIVERSAL BATTERY HOLDER (UBH)
The all-rounder among battery holders - designed for cylindrical 18650 cells as well as button cells - with high flexibility in dimensions and connection options

 

GAMRY BATTERY HOLDER FOR COIN CELLS (DUAL-CR2032) AND 18650 (DUAL-18650)
For electrochemical impedance spectroscopy on the coin cell types CR2016, CR2025 and CR2032 or on the cylindrical 18650 cell

 

GAMRY RDE710 - ROTATING DISK- (RDE), -RING-DISK- (RRDE) OR -CYLINDER ELECTRODE (RCE)
RDE710 Rotator for RDE, RRDE and RCE is designed for hydrodynamically controlled electrode reactions both for the characterization of catalysts and for determining flow-induced corrosion rates.

 

GAMRY - DR. BOB´S CELL KIT
Dr. Bob´s Cell Kit is made entirely of inert materials and is used in a variety of applications to characterize unknown electroactive species.

 

GAMRY DYE SOLAR CELL TESTING KIT (IMPS / IMVS) WITHOUT BIPOTENTIOSTAT SYSTEM
This experimental setup of a synchronized bipotentiostat and an optical bench is used for the detailed characterization of dye solar cells

 

GAMRY WORKING ELECTRODES
Working electrodes of different dimensions and inert materials

 

HOT DISK TPS 2500S
The Hot Disk TPS 2500 S is the flagship instrument in the system portfolio of Hot Disk AB and covers an extensive range of materials of various geometries and dimensions - meets ISO Standard 22007-2.

 

HOT DISK TPS 3500
Testing the extreme – when you have very small and very high conductive samples this is the ideal instrument for testing heat conductivity, thermal diffusivity and specific heat.

 

THINKY ARE-250
Mixing and defoaming without vacuum in one step – with patented defoaming mode

 

THINKY ARM-310
Mixing and defoaming without vacuum in one step

 

THINKY SR-500
Mixing, warming and defoaming of solder paste – without vacuum in one single step.

 

CALMETRIX I-CAL FLEX ISOTHERMAL HEAT FLOW CALORIMETER
The universal and modular calorimeter for materials research and life science

 



Request a quote

Technical support

Contact us!

Request a quote Technical support Contact us!
COOKIE-SETTINGS    ///   LINKS AND GTC    ///   IMPRINT    ///   DATA PROTECTION    ///   PRODUCTS    ///   DIESE SEITE AUF DEUTSCH